J. Ocean Eng. Technol. Search

CLOSE


J. Ocean Eng. Technol. 1996;10(4):103-108.    

The behavior of corrosion potential in the mortar-embedded
부식된 철근을 사용한 모르타르의 환경에 따른 부식전위의 거동
이상호,한정섭,권순석
동아대학교 해양공학과 대학원,경상대학교 수산대학 선박기계공학과,동아대학교 공과대학 기계공학과
© 1996 The Korean Society of Ocean Engineers     Open access / Under a Creative Commons License
Keywords: Indoor Air Control, Mied Convection, Rectangular, Enclosure, Minimum Cell, Outlet, Holographic interferometry
핵심용어: 실내공기제어, 혼합대류, 사각공간, 최소셀, 유출구, 홀로그래픽 간섭계
Abstract
To syudy the change of prtential in the mortar-embedded precorroded rebar, a half cell method was adapted. The rebar was corroded by the salt spray and then the rebar embedded in the mortar. A saturated copper sulfate feference electrode was used. The corrosion potential of the rebar in the mortar specimen cured in air was increased, whereas that of the rebar cured in water was decreased with aging. The corrosion potential of the rebar in the mortar was decreased with corroded time by the salt spray. As the mortar thickness covered the rebar was increased, the corrosion potential of the rebar in the mortar was increased.